File #: 24-0088SP    Name: Mobile Mounting Solutions Addition
Type: Agenda Item Status: Regular Agenda Item
In control: Planning & Zoning Commission
On agenda: 2/11/2025 Final action:
Title: Conduct a Public Hearing to Consider/Discuss/Act on Design Exceptions to a Site Plan (Mobile Mounting Solutions), Located at 406 Interchange Street.
Attachments: 1. Standard Conditions Checklist, 2. Location Map and Aerial Exhibit, 3. Letter of Intent, 4. Ex. PD Ord. No. 1465, 5. Proposed Site Plan, 6. Proposed Landscape Plan, 7. Presentation
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.
Title
Conduct a Public Hearing to Consider/Discuss/Act on Design Exceptions to a Site Plan (Mobile Mounting Solutions), Located at 406 Interchange Street.
Summary
COUNCIL GOAL: Direction for Strategic and Economic Growth (1C: Provide a strong city economy by facilitating a balance between industrial, commercial, residential, and open space)
MEETING DATE: February 11, 2025
DEPARTMENT: Development Services - Planning Department

CONTACT: Stewart Starry, Planner I
Caitlyn Strickland, AICP, Planning Manager
Jennifer Arnold, AICP, Director of Planning

APPROVAL PROCESS: The action of the Planning and Zoning Commission for the proposed site plan may be appealed to the City Council.
STAFF RECOMMENDATION: Staff recommends approval of the proposed site plan with the following conditions:
1. The applicant receive approval of the following:
a. A Design Exception to Section 206A.5.c of the Unified Development Code (UDC) to reduce the required tree planting ratio within the street buffer from 1:30 linear feet to 1:74 linear feet.
2. The applicant revise the Landscape plan to:
a. Reflect the updated tree planting ratio requirement within the street buffer.
b. Update the landscape plan to include an affidavit stating that all required landscape areas shall be provided with an automatic underground irrigation system with rain and freeze sensors and said irrigation system shall be designed by a qualified professional and installed by a licensed irrigator.
Prior to issuance of a building permit:
1. The applicant satisfy the conditions as shown on the Standard Conditions for Site Plan Approval Checklist, attached.
APPLICATION SUBMITTAL DATE: October 15, 2024 (Original Application)
November 18, 2024 (Revised Submittal)
December 17, 2024 (Revised Submittal)
January 03, 2025 (Revised Submittal)
January 11, 2025 (Revised Submittal)

ITEM SUMMARY: The applicant proposes to add 13,224 square feet of warehouse to an existing 13,600 square foot O...

Click here for full text